LV-N11CP KEYENCE Multi-Purpose Digital Laser Sensor
LV-N11CP Amplifier, M8 Connector, Main unit, PNP
Model | LV-N11CP | |
Type | 1 output | |
Output | PNP | |
Cable/connector | M8 connector | |
Main/Expansion unit | Main unit | |
I/O | Control outputs | 1 output |
External input | 1 input | |
Monitor output | None | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, | |
Timer duration selectable: 1 ms to 9,999 ms, | ||
Maximum error against the setting value: ±10% max. | ||
Control outputs | PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) | |
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less | ||
(Multiple connections) 1 output max: 20 mA or less | ||
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Number of interference | Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA, | |
prevention units | Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm × W 9.8 mm × L 78.7 mm | |
Unit expansion | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power | Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4 | |
consumption | Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*4 | |
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V) | ||
*5 | ||
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 20 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected | ||
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. | ||
*3 These numbers double when "DOUBLE" is selected. | ||
*4 Increases 30 mW (1 mA) for High Speed mode. | ||
*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. | ||
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. | ||
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max. | ||
*6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. | ||
One or two more units connected: -20 °C to +55 °C ; 3 to 10 more units connected: -20 °C to +50 °C; 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |